Triple pane insulating glass unit

1.

Surface 2 is coated with LoE

2.

2

-270 to reject the sun’s heat

The airspaces are filled with argon gas* to further prevent

3.

solar heat gain in summer and heat loss in winter

Thermo-Edge, stainless steel spacer bars helps prevent heat

4.

loss, reduce potential for condensation, and improve overall

U-factor

Surface 5 is coated with LoE

5.

2

-180 to further augment the

insulating value

4

Surface 4

Surface 6

(indoors)

Surface 5

Surface 1

(outdoors)

3

3

2

5

1

Surface 2

Surface 3

Product

Glass Type

Performance

Grade

U-Factor

R-Value

SHGC

VT

Crank-out Casement

LoE

2

-270 #2 / LoE

2

-180 #5

R-PG50

0.19

5.3

0.23

0.41

Crank-out Awning

LoE

2

-270 #2 / LoE

2

-180 #5

R-PG50

0.19

5.3

0.23

0.41

Studio

LoE

2

-270 #2 / LoE

2

-180 #5

CW-PG50

0.18

5.6

0.26

0.49

Transom

LoE

2

-270 #2 / LoE

2

-180 #5

CW-PG50

0.18

5.6

0.26

0.49

Radius Unit

LoE

2

-270 #2 / LoE

2

-180 #5

CW-PG50

0.18

5.6

0.26

0.49

Geometric Unit

LoE

2

-270 #2 / LoE

2

-180 #5

CW-PG50

0.18

5.6

0.26

0.49

Sliding Patio Door

LoE

2

-270 #2 / LoE

2

-180 #5

LC-PG50

0.23

4.3

0.22

0.40

Energy Performance (EP) units are built to meet or exceed strict

energy requirements. Insulating values are nearly twice that

which is currently required by ENERGY STAR

®

. Plus, they

exceed 2010 ENERGY STAR criteria for most climate zones in

the U.S. and Canada.

Casements, awnings, studio, transom, radius, geometric and

sliding patio doors are available as Energy Performance units.

A triple pane glazing system helps these products achieve a

remarkable energy performance rating of R5 for windows and

over an R4 for sliding patio doors.

Windquest EP units allow for a maximum air infiltration of only

.01 cubic feet per minute, which is 30 times better than the

industry standard.

The above LoE combination was chosen as the standard for EP units to optimize U-Factor, visible transmittance (VT), SHGC,

and external appearance. Other LoE options are available to meet specific needs or passive solar requirements; check with your

local Kolbe dealer for further information.

G

l a z i n g

S

y s t e m

U

n i t

P

e r f o r m a n c e

* Argon gas may not be included with units to be installed in or shipped through high altitude areas.

NOTES:

Values listed in chart are simulated results including argon gas fill; please check with your Kolbe dealer for further information.

For the most up-to-date test results, visit

www.kolbe-kolbe.com

.

For energy performance terminology, refer to page 76.