Table of Contents Table of Contents
Previous Page  77 / 80 Next Page
Information
Show Menu
Previous Page 77 / 80 Next Page
Page Background www.kolbe-kolbe.com

77

E

n e r g y

P

e r f o r m a n c e

D

ata

Energy Star

®

C

anada

Products may comply for Canada’s Energy

Star program based on two compliance

paths: either their U-factor total, or their

Energy Rating (ER). The Energy Rating is

based on a product’s overall performance

based on three criteria: (1) solar heat gain,

(2) heat loss through the frame, spacer and glass, and (3)

air leakage loss. The higher the ER number, the better the

product’s thermal performance.

The U-factor and ER criteria for Canada’s four climate zones is

shown in the charts provided. For more detailed information

about their Energy Rating system and Kolbe products that

qualify for Canada’s Energy Star Program, visit their

website at

www.oee.nrcan.gc.ca/energystar.

n

ating

entral

Cooling

entral

Cooling

n

oling

Zone A

Southwestern Canada/

British Columbia

Zone B

Southern Canada

Zone C

Central Canada

Zone D

Northern Canada

Zone A

Southwestern Canada/

British Columbia

Zone B

Southern Canada

Zone C

Central Canada

Zone D

Northern Canada

Zone A

Southwestern Canada/

British Columbia

Zone B

Southern Canada

Zone C

Central Canada

Zone D

Northern Canada

U-Factor CONVERSION

Imperial

Metric

0.35

2.00

0.32

1.80

0.28

1.60

0.25

1.40

0.21

1.20

Zone

Compliance Paths

Minimum Energy Rating

(ER)**

or

Maximum

U-Factor

A

21

(Max. U-factor 0.35)

or

< 0.32

(Min. ER = 13)

B

25

(Max. U-factor 0.35)

or

< 0.28

(Min. ER = 17)

C 29

(Max. U-factor 0.35)

or

< 0.25

(Min. ER = 21)

D 34

(Max. U-factor 0.35)

or

< 0.21

(Min. ER = 25)

ENERGY STAR - Canada Qualification Criteria

for Windows after October 1, 2010

**

After June 1, 2010: Both fixed and operable windows will have to meet the same ER

level for each climate zone.

Zone

Compliance Paths

Minimum Energy Rating

(ER)

or

Maximum

U-Factor

A

21

(Max. U-factor 0.35)

or

< 0.32

B

25

(Max. U-factor 0.35)

or

< 0.28

C 29

(Max. U-factor 0.35)

or

< 0.25

D 34

(Max. U-factor 0.35)

or

< 0.21

ENERGY STAR - Canada Qualification Criteria

for Doors

after October 1, 2010

Criteria shown applies to both sliding and hinged doors and in all four climate zones.

Doors following the “Maximum U-factor” compliance path do not have a minimum ER

requirement.

NOTE:

Energy performance data and air, water, structural data is updated on a continuous basis. For the most

current information, visit

www.kolbe-kolbe.com