Table of Contents Table of Contents
Previous Page  223 / 224 Next Page
Information
Show Menu
Previous Page 223 / 224 Next Page
Page Background

ENERGY STAR

®

– Canada

Products may comply for Canada’s

ENERGY STAR program based on these

compliance paths: their total U-factor, their

Energy Rating (ER), or both. The Energy

Rating is based on a product’s overall

performance based on three criteria: (1)

solar heat gain, (2) U-factor, and (3) average

air tightness. The higher the ER number, the better the

product’s thermal performance.

The U-factor and ER criteria for Canada’s three climate

zones is shown in the charts provided. For more detailed

information about their Energy Rating system and Kolbe

products that qualify for Canada’s ENERGY STAR Program,

visit their website at

www.oee.nrcan.gc.ca/energystar.

NOTE: Energy performance data and air, water, structural data is updated on a continuous basis. For the most current information, visit

www.kolbe-kolbe.com

or contact

your local Kolbe dealer.

Zone A

Southwestern Canada/

British Columbia

Zone B

Southern Canada

Zone C

Central Canada

Zone D

Northern Canada

Zone A

Southwestern Canada/

British Columbia

Zone B

Southern Canada

Zone C

Central Canada

Zone D

Northern Canada

Zone A

Southwestern Canada/

British Columbia

Zone B

Southern Canada

Zone C

Central Canada

Zone D

Northern Canada

U-FACTOR CONVERSION

Imperial

Metric

0.35

2.00

0.32

1.80

0.28

1.60

0.25

1.40

0.21

1.20

Zone

COMPLIANCE PATHS

Minimum Energy Rating

(ER)**

or

Maximum

U-Factor

A

21

(Max. U-factor 0.35)

or

< 0.32

(Min. ER = 13)

B

25

(Max. U-factor 0.35)

or

< 0.28

(Min. ER = 17)

C 29

(Max. U-factor 0.35)

or

< 0.25

(Min. ER = 21)

D 34

(Max. U-factor 0.35)

or

< 0.21

(Min. ER = 25)

ENERGY STAR - Canada Qualification Criteria

for Windows and Sliding Doors

after February 1, 2015

**

After June 1, 2010: Both fixed and operable windows will have to meet the same ER

level for each climate zone.

Zone

COMPLIANCE PATHS

Minimum Energy Rating

(ER)

or

Maximum

U-Factor

A

21

(Max. U-factor 0.35)

or

< 0.32

B

25

(Max. U-factor 0.35)

or

< 0.28

C 29

(Max. U-factor 0.35)

or

< 0.25

D 34

(Max. U-factor 0.35)

or

< 0.21

ENERGY STAR - Canada Qualification Criteria

for Doors

after October 1, 2010

Criteria shown applies to both sliding and hinged doors and in all four climate zones.

Doors following the “Maximum U-factor” compliance path do not have a minimum ER

requirement.

223