Table of Contents Table of Contents
Previous Page  209 / 224 Next Page
Information
Show Menu
Previous Page 209 / 224 Next Page
Page Background

209

Kolbe Ultra Series

Product

#

Sq. Ft.

Clear

Opg.

Clear Opening

Sq. Ft.

D.L.O.

Sq. Ft.

Vent

Sq. Ft.

of Unit

Frame

Dim.

Width

Height

Crank-Out Casements (continued)

E14

7.71 25-3/4"

43-1/8"

8.56

9.64

12.00

E146

8.78 25-3/4"

49-1/8"

9.80

10.98

13.50

E15

9.86 25-3/4"

55-1/8"

11.03 12.32

15.00

E156

10.93 25-3/4"

61-1/8"

12.27 13.66

16.50

E16

12.00 25-3/4"

67-1/8"

13.50 15.00

18.00

Product

#

Sq. Ft.

Clear

Opg.

Clear Opening

Sq. Ft.

D.L.O.

Sq. Ft.

Vent

Sq. Ft.

of Unit

Frame

Dim.

Width

Height

Crank-Out Casements

S12

0.92 6-15/16"

19-1/8"

1.18

1.54

2.67

S126

1.21 6-15/16"

25-1/8"

1.58

2.02

3.33

S13

1.50 6-15/16"

31-1/8"

1.98

2.50

4.00

S136

1.79 6-15/16"

37-1/8"

2.38

2.98

4.67

S14

2.08 6-15/16"

43-1/8"

2.78

3.46

5.33

S146

2.37 6-15/16"

49-1/8"

3.18

3.94

6.00

S15

2.66 6-15/16"

55-1/8"

3.58

4.43

6.67

S156

2.94 6-15/16"

61-1/8"

3.99

4.91

7.33

S16

3.23 6-15/16"

67-1/8"

4.39

5.39

8.00

N12

1.45 10-15/16" 19-1/8"

1.67

2.07

3.33

N126

1.91 10-15/16" 25-1/8"

2.24

2.72

4.17

N13

2.36 10-15/16" 31-1/8"

2.80

3.36

5.00

N136

2.82 10-15/16" 37-1/8"

3.37

4.01

5.83

N14

3.28 10-15/16" 43-1/8"

3.94

4.66

6.67

N146

3.73 10-15/16" 49-1/8"

4.51

5.31

7.50

N15

4.19 10-15/16" 55-1/8"

5.07

5.96

8.33

N156

4.64 10-15/16" 61-1/8"

5.64

6.61

9.17

N16

5.10 10-15/16" 67-1/8"

6.21

7.25

10.00

W12

1.98 14-15/16" 19-1/8"

2.16

2.60

4.00

W126

2.61 14-15/16" 25-1/8"

2.89

3.41

5.00

W13

3.23 14-15/16" 31-1/8"

3.63

4.23

6.00

W136

3.85 14-15/16" 37-1/8"

4.36

5.04

7.00

W14

4.47 14-15/16" 43-1/8"

5.09

5.86

8.00

W146

5.10 14-15/16" 49-1/8"

5.83

6.67

9.00

W15

5.72 14-15/16" 55-1/8"

6.56

7.49

10.00

W156

6.34 14-15/16" 61-1/8"

7.30

6.34

11.00

W16

6.96 14-15/16" 67-1/8"

8.03

9.12

12.00

L12

2.52 18-15/16" 19-1/8"

2.65

3.13

4.67

L126

3.30 18-15/16" 25-1/8"

3.55

4.11

5.83

L13

4.09 18-15/16" 31-1/8"

4.45

5.09

7.00

L136

4.88 18-15/16" 37-1/8"

5.35

6.07

8.17

L14

5.67 18-15/16" 43-1/8"

6.25

7.06

9.33

L146

6.46 18-15/16" 49-1/8"

7.15

8.04

10.50

L15

7.25 18-15/16" 55-1/8"

8.05

9.02

11.67

L156

8.04 18-15/16" 61-1/8"

8.95

10.00 12.83

L16

8.83 18-15/16" 67-1/8"

9.86

10.98 14.00

Product

#

Sq. Ft.

Clear

Opg.

Clear Opening

Sq. Ft.

D.L.O.

Sq. Ft.

Vent

Sq. Ft.

of Unit

Frame

Dim.

Width Height

Crank-Out Casements (continued)

X12

2.78 20-15/16" 19-1/8"

2.89

3.40

5.00

X126

3.65 20-15/16" 25-1/8"

3.88

4.46

6.25

X13

4.53 20-15/16" 31-1/8"

4.86

5.53

7.50

X136

5.40 20-15/16" 37-1/8"

5.84

6.59

8.75

X14

6.27 20-15/16" 43-1/8"

6.83

7.66

10.00

X146

7.14 20-15/16" 49-1/8"

7.81

8.72

11.25

X15

8.02 20-15/16" 55-1/8"

8.80

9.79

12.50

X156

8.89 20-15/16" 61-1/8"

9.78

10.85

13.75

X16

9.76 20-15/16" 67-1/8"

10.77 11.92

15.00

E13

5.39 24-15/16" 31-1/8"

6.09

6.82

9.00

E136

6.43 24-15/16" 37-1/8"

7.33

8.14

10.50

E14

7.47 24-15/16" 43-1/8"

8.56

9.45

12.00

E146

8.51 24-15/16" 49-1/8"

9.80

10.77

13.50

E15

9.55 24-15/16" 55-1/8"

11.03 12.08

15.00

E156

10.59 24-15/16" 61-1/8"

12.27 13.40

16.50

E16

11.62 24-15/16" 67-1/8"

13.50 14.71

18.00

Note For Push-out Casement Windows:

}

Clear opening widths shown are for units with friction hinges

and no screen. If the following screen options are used, the

clear opening widths will need to be adjusted as noted:

Swinging screen:

- Vent area decreases by 7%

Retractable screen:

- Vent area decreases by 23%

- Subtract 21/32" for clear opening width

- Subtract 2-13/16" for clear opening height

Friction Adjuster with no screen or with swinging screen:

- Add 4-15/32"

(or 5-31/32" for “E” Series)

for clear

opening width

Friction Adjuster with retractable screen:

- Add 3-13/16"

(or 5-5/16" for “E” Series)

for clear

opening width

}

Two sash open may or may not be considered as an

acceptable emergency escape and rescue opening per the

local building inspector

}

Shaded units meet most national building codes for

emergency escape and rescue requirements

NOTE: For the most up-to-date data, please visit the Kolbe website at