153

Kolbe Ultra Series

NOTE: All measurements are nominal. Elevation charts are not to scale.

Operation is viewed from the interior. When ordering single units, specify stationary, hinged left or hinged right.

Divided lites are optional. The divided lite configuration shown for a single panel is typical for each panel in the unit.

Additional swinging door sizes are available in the Entrance Door section.

Some installation procedures will require a larger rough opening than noted

(i.e. installations utilizing our installation clips)

, therefore, you may need to increase the rough

opening size accordingly. Rough opening gaps may be increased up to a maximum of 1/2" on all sides and still be within good practice guidelines. For rough opening

recommendations, see pg. 208.

F.S. = Frame Size • R.O. = Rough Opening • G.S. = Glass Size

(Glass sizes are shown per panel.)

Inswing Patio Doors

F.S.

R.O.

G.S.

Inswing Patio Door

2'-6 1/4"

2'-6 3/4"

20 5/16"

4'-11 7/16"

4'-11 15/16"

20 5/16"

7'-4 5/8"

7'-5 1/8"

20 5/16"

6'-7 1/2"

6'-8"

65 11/16"

7'-11 5/8"

8'-0 1/8"

81 3/4"

SPU2666 SPU41166AS

SPU2680 SPU41180AS

4'-11 7/16"

4'-11 15/16"

20 5/16"

SPU41166SA

SPU41180SA

SPU7566SASR

SPU7580SASR

ACT

ACT

STAT

ACT

STAT

STAT

7'-4 5/8"

7'-5 1/8"

20 5/16"

SPU7566SASL

SPU7580SASL

ACT

STAT

STAT

ACT

STAT

STAT

ACT

STAT

STAT

STAT

ACT

ACT

STAT

STAT

3'-0 1/4"

3'-0 3/4"

26 5/16"

SPU3066

SPU3080

5'-11 7/16"

5'-11 15/16"

26 5/16"

SPU51166AS

SPU51180AS

ACT

STAT

5'-11 7/16"

5'-11 15/16"

26 5/16"

SPU51166SA

SPU51180SA

ACT

STAT

ACT

STAT

ACT

STAT

8'-10 5/8"

8'-11 1/8"

26 5/16"

SPU81166SASR

SPU81180SASR

8'-10 5/8"

8'-11 1/8"

26 5/16"

SPU81166SASL

SPU81180SASL

ACT

STAT

STAT

ACT

STAT

STAT

ACT

STAT

STAT

ACT

STAT

STAT

Elevation charts provide frame sizes for units without brickmould.

Below are the calculations to determine overall unit dimensions for

units with brickmould.

1 15/16” brickmould; F.S. to U.D.

+2 5/8"

+1 5/16"

3 1/2” flat or profiled casing; F.S. to U.D.

+5 1/2"

+2 3/4"

3 1/2” flat casing & backband; F.S. to U.D.

+7"

+3 1/2"

Dimension Calculations

F.S. to Panel O.S.M.

(1-wide, active)

-1 13/16" -2 23/32"

(1-wide, stationary)

-1 3/4"

-2 23/32"

(2-wide)

-2 9/16"÷2 -2 23/32"

(3-wide)

-3 5/16"÷3 -2 23/32"

Panel O.S.M. to G.S.

-8 1/8"

-11 3/32"

G.S. to D.L.O.

-1"

-1"

Note

:

Clear opening dimensions can be found on pg. 216.

Width Height

F.S. = Frame Size • G.S. = Glass Size • O.S.M. = Outside Measurement

D.L.O. = Daylight Opening • U.D. = Unit Dimension

Operation is viewed from the interior.

Inswing Patio Doors

Elevation Charts