Page Background

U.D.

R.O.

G.S.*

G.S.**

Segment Head Casements - “W” Series

2'-8"

2'-6 1/2"

25 1/4"

23 13/16"

3'-2"

3'-0 1/2"

31 1/4"

29 13/16"

3'-8"

3'-6 1/2"

37 1/4"

35 13/16"

4'-2"

4'-0 1/2"

43 1/4"

41 13/16"

4'-8"

4'-6 1/2"

49 1/4"

47 13/16"

5'-2"

5'-0 1/2"

55 1/4"

53 13/16"

5'-8"

5'-6 1/2"

61 1/4"

59 13/16"

6'-2"

6'-0 1/2"

67 1/4"

65 13/16"

2'-2 1/2"

2'-0 1/2"

19 1/4"

17 13/16"

W13-SEG

W23-SEG

W33-SEG

W14-SEG

W24-SEG

W34-SEG

W15-SEG

W25-SEG

W35-SEG

W16-SEG

W26-SEG

W36-SEG

W156-SEG W256-SEG

W356-SEG

W146-SEG W246-SEG

W346-SEG

W136-SEG W236-SEG

W336-SEG

W126-SEG†

W226-SEG†

W326-SEG†

4'-2 1/2"

4'-0 1/2"

19 1/4"

17 13/16"

6'-2 1/2"

6'-0 1/2"

19 1/4"

17 13/16"

4

7

10

4

7

10

4

7

10

4

7

10

4

7

10

7

4

10

7

4

10

7

4

10

4

4

4

4

4

7

7

7

7

7

11

11

4

4

4

7

7

7

U.D.

R.O.

G.S.*

G.S.**

Segm entHead Casem ents-“L”Series

2'-8"

2'-6 1/2"

25 1/4"

23 13/16

3'-2"

3'-0 1/2"

31 1/4"

29 13/16"

3'-8"

3'-6 1/2"

37 1/4"

35 13/16"

4'-2"

4'-0 1/2"

43 1/4"

41 13/16"

4'-8"

4'-6 1/2"

49 1/4"

47 13/16"

5'-2"

5'-0 1/2"

55 1/4"

53 13/16"

5'-8"

5'-6 1/2"

61 1/4"

59 13/16"

6'-2"

6'-0 1/2"

67 1/4"

65 13/16"

2'-6 1/2"

2'-4 1/2"

23 1/4"

21 13/16"

4'-10 1/2"

4'-8 1/2"

23 1/4"

21 13/16"

7'-2 1/2"

7'-0 1/2"

23 1/4"

21 13/16"

1

1

1

14

4

14

4

1

1

1

4

4

11

11

11

11

11

11

Segment Head Casements

“W” Series

Segment Head Casements

“L” Series

NOTE: All measurements are nominal. Elevation charts are not to scale.

Divided lites are optional. The divided lite configurations shown for single sash are typical for each sash of mulled units.

Some installation procedures will require a larger rough opening than noted (i.e. installations utilizing our installation clips), therefore, you may need to increase the rough

opening size accordingly. Rough opening gaps may be increased up to a maximum of 1/2" on all sides and still be within good practice guidelines. For rough opening

recommendations, see pg. 196.

* Approximate glass sizes per sash are given; true glass sizes vary depending on the radius involved.

** Glass size for push-out casements.

† Push-out units are only available with single-point hardware.

PRODUCT CODES: To order, add “KW” before the product number (Ex: W24-SEG). For push-out casements, have dealer specify push-out when placing order for unit.

Specify stationary, left or right venting when ordering single units. Venting is viewed from the window exterior.

U.D. = Unit Dimension • R.O. = Rough Opening • G.S. = Glass Size (Glass sizes are shown per sash)

39