Table of Contents Table of Contents
Previous Page  37 / 208 Next Page
Information
Show Menu
Previous Page 37 / 208 Next Page
Page Background

U.D.

R.O.

G.S.*

G.S.**

2'-8"

2'-6 1/2"

25 1/4"

23 13/16

"

3'-2"

3'-0 1/2"

31 /4"

29 13/16

"

3'-8"

3'-6 1/2"

37 1/4"

35 13/16

"

4'-2"

4'-0 1/2"

43 1/4"

41 13/16

"

4'-8"

4'-6 1/2"

49 1/4"

47 13/16

"

5'-2"

5'-0 1/2"

55 1/4"

53 13/16

"

5'-8"

5'-6 1/2"

61 1/4"

59 13/16

"

6'-2"

6'-0 1/2"

67 1/4"

65 13/16

"

1'-6 1/2"

1'-4 1/2"

11 1/4"

9 13/16

"

S13-SEG

S14-SEG

S15-SEG

S16-SEG

S156-SEG

S146-SEG

S136-SEG

S126-SEG†

4

4

4

4

4

4

4

4

1'-10 1/2"

1'-8 1/2"

15 1/4"

13 13/16

"

N13-SEG

N14-SEG

N15-SEG

N16-SEG

N156-SEG

N146-SEG

N136-SEG

N126-SEG†

4

4

4

4

4

4

4

4

2'-2 1/2"

2'-0 1/2"

19 1/4"

17 13/16

"

W13-SEG

W14-SEG

W15-SEG

W16-SEG

W156-SEG

W146-SEG

W136-SEG

W126-SEG†

4

4

4

4

4

4

4

4

2'-8 1/2"

2'-6 1/2"

25 1/4"

23 13/16

"

X13-SEG

X14-SEG***

X15-SEG***

X16-SEG***

X156-SEG***

X146-SEG***

X136-SEG

X126-SEG†

5

5

5

5

5

5

5

5

E13-SEG

E14-SEG***

E15-SEG***

E16-SEG***

E156-SEG***

E146-SEG***

E136-SEG***

5

5

5

5

5

5

5

3'-2 1/2"

3'-0 1/2"

31 1/4"

29 13/16

"

Segment Head Casements - Single Units

4

4

4

4

4

4

4

4

L126-SEG†

L13-SEG

L136-SEG

L14-SEG

L146-SEG

L15-SEG

L156-SEG

L16-SEG

2'-6 1/2"

2'-4 1/2"

23 1/4"

21 13/16

"

2'-10 1/2"

2'-8 1/2"

27 1/4"

25 13/16

"

C13-SEG

C14-SEG***

C15-SEG***

C16-SEG***

C156-SEG***

C146-SEG***

C136-SEG

C126-SEG†

5

5

5

5

5

5

5

5

Segment Head Casements | Single Units

NOTE: All measurements are nominal. Elevation charts are not to scale.

Divided lites are optional.

Some installation procedures will require a larger rough opening than noted (i.e. installations utilizing our installation clips), therefore, you may need to increase the rough

opening size accordingly. Rough opening gaps may be increased up to a maximum of 1/2" on all sides and still be within good practice guidelines. For rough opening

recommendations, see pg. 196.

* Approximate glass sizes are given; true glass sizes vary depending on the radius involved.

** Glass size for push-out casements.

*** Units meet most national emergency escape and rescue requirements.

† Push-out units are only available with single-point hardware.

PRODUCT CODES:

To order, add “KW” before the product number (Ex: KWN16-SEG). For push-out casements, have dealer specify push-out when placing order for unit. Specify stationary,

left or right venting when ordering single units. Venting is viewed from the window exterior.

U.D. = Unit Dimension • R.O. = Rough Opening • G.S. = Glass Size

37

Kolbe Heritage Series